Feedback

Faculté des Sciences appliquées
Faculté des Sciences appliquées
Mémoire
VIEW 90 | DOWNLOAD 14

Comparative analysis of the fire performance of columns made of normal concrete and high strength concrete

Télécharger
Peric, Vlado ULiège
Promoteur(s) : Gernay, Thomas ULiège
Date de soutenance : 27-jui-2016/28-jui-2016 • URL permanente : http://hdl.handle.net/2268.2/1461
Détails
Titre : Comparative analysis of the fire performance of columns made of normal concrete and high strength concrete
Titre traduit : [fr] Analyse comparative de la résistance au feu des colonnes réalisées en béton normal et en béton haute résistance
Auteur : Peric, Vlado ULiège
Date de soutenance  : 27-jui-2016/28-jui-2016
Promoteur(s) : Gernay, Thomas ULiège
Membre(s) du jury : Franssen, Jean-Marc ULiège
Mihaylov, Boyan ULiège
Molkens, Tom 
Langue : Anglais
Mots-clés : [en] Fire, Column, High Strength Concrete, Tall Building, Numerical Analysis
[en] SAFIR
Discipline(s) : Ingénierie, informatique & technologie > Ingénierie civile
Public cible : Chercheurs
Professionnels du domaine
Etudiants
Institution(s) : Université de Liège, Liège, Belgique
Diplôme : Master en ingénieur civil des constructions, à finalité approfondie
Faculté : Mémoires de la Faculté des Sciences appliquées

Résumé

[en] Considering the use of High strength concrete (HSC) when designing concrete buildings has nowadays become a widespread practice. Choosing HSC as opposed to a normal strength concrete (NSC) becomes relevant when parameters such as cross section reductions, layout modification or self-weight gains are considered.

Plausible issues are met when reducing cross sections towards dimensions where fire resistance problems can occur. Indeed, using smaller HSC cross sections undeniably leads to a faster element’s heating. In addition, HSC encounters higher strength losses and explosive spalling, both not working to its benefit. Explosive spalling resulting from the development of internal pore pressures has not been taken into account for this project. Preventing concrete spalling has been accomplished considering a sufficient amount of polypropylene fibers within the initial mixtures.

This master thesis considers the Eurocode design of a parking garage structure where circular columns have been designed using NSC and HSC, pointing out the plausible cross section reductions. Numerical simulations have then been conducted with the software SAFIR® for the propotype columns related to 5, 10 and 15 stories. Time-resistance curves have been plotted indicating fire resistances RF exceeding three hours for every column. Theoretical modifications have moreover been conducted in order to pursue the limits of the HSC use. The former showed that parameters such as height or support conditions do not significantly aggravate HSC’s fire properties.


Fichier(s)

Document(s)

File
Access TFE.pdf
Description:
Taille: 12.06 MB
Format: Adobe PDF

Annexe(s)

File
Access Résumé.pdf
Description:
Taille: 280.02 kB
Format: Adobe PDF
File
Access Abstract.pdf
Description:
Taille: 263.61 kB
Format: Adobe PDF

Auteur

  • Peric, Vlado ULiège Université de Liège > Master ingé. civ. constr., fin. appr. (ex 2e master)

Promoteur(s)

Membre(s) du jury

  • Nombre total de vues 90
  • Nombre total de téléchargements 14










Tous les documents disponibles sur MatheO sont protégés par le droit d'auteur et soumis aux règles habituelles de bon usage.
L'Université de Liège ne garantit pas la qualité scientifique de ces travaux d'étudiants ni l'exactitude de l'ensemble des informations qu'ils contiennent.