Feasibility study of three-dimensional patient-specific simulation of glenohumeral range of motion.
Dirick, Thomas
Promoteur(s) :
Schwartz, Cédric
Date de soutenance : 30-jui-2025/1-jui-2025 • URL permanente : http://hdl.handle.net/2268.2/23345
Détails
| Titre : | Feasibility study of three-dimensional patient-specific simulation of glenohumeral range of motion. |
| Titre traduit : | [fr] Étude de faisabilité d'une simulation 3D spécifique au patient de la portée de mouvement de l'articulation gléno-humérale. |
| Auteur : | Dirick, Thomas
|
| Date de soutenance : | 30-jui-2025/1-jui-2025 |
| Promoteur(s) : | Schwartz, Cédric
|
| Membre(s) du jury : | Bruls, Olivier
Ruffoni, Davide
Meynen, Alexander |
| Langue : | Anglais |
| Nombre de pages : | 66 |
| Mots-clés : | [en] Glenohumeral Joint [en] Range of motion [en] Shoulder instability [en] Patient-specific modeling [en] Anatomical constraints [en] Feasibility study [en] Orthopaedic biomechanics |
| Discipline(s) : | Ingénierie, informatique & technologie > Ingénierie mécanique Sciences de la santé humaine > Orthopédie, rééducation & médecine sportive |
| Institution(s) : | Université de Liège, Liège, Belgique |
| Diplôme : | Master en ingénieur civil biomédical, à finalité spécialisée |
| Faculté : | Mémoires de la Faculté des Sciences appliquées |
Résumé
[en] Shoulder instability is a common clinical problem, especially in patients with bone defects like Hill-Sachs or bony Bankart lesions. Today, most preoperative tools are made for shoulder replacements and do not help evaluate joint stability in patients who need bone-preserving surgeries. This thesis aims to fill that gap by developing a patient-specific simulation tool that estimates the range of motion (ROM) of the glenohumeral joint using 3D computed tomography (CT) scans of the scapula and humerus.
The main goal is to identify which joint configurations are stable and which are not, using a set of anatomical constraints. The simulation works in two steps: first, it samples possible positions in a wide area, and then it uses a binary search to refine the boundaries of the valid space. Several constraints are used to evaluate each position, including bone collision, glenoid coverage, distances between bones, and tuberosity orientation.
The method was tested on five different patients. Results showed that bone defects, especially glenoid bone loss, reduced the amount of valid movement. Among the constraints, glenoid coverage was the most common reason for rejecting a joint position, followed by acromiohumeral and coracohumeral distances. Finally, a clinical application is presented to evaluate whether Hill-Sachs lesions engage within the computed range of motion. The results indicate that the risk of engagement depends more on the location of the defect than on its size. Notably, some engagements were observed even in near-neutral arm positions, not only at the boundaries of the ROM.
In conclusion, this feasibility study presents an approach for simulating glenohumeral motion using patient-specific CT data. While the tool provides an initial framework for exploring joint stability, its current limitations prevent clinical application. Further work is required to determine whether these limitations can be overcome in future developments.
Fichier(s)
Document(s)
Annexe(s)
Citer ce mémoire
L'Université de Liège ne garantit pas la qualité scientifique de ces travaux d'étudiants ni l'exactitude de l'ensemble des informations qu'ils contiennent.

Master Thesis Online


Tous les fichiers (archive ZIP)
ThomasDirick_MasterThesis.pdf