Feedback

Faculté des Sciences appliquées
Faculté des Sciences appliquées
Mémoire

Master thesis : Process validation in additive manufacturing for custom bone implants: Strategy and Optimization

Télécharger
Malien, Téa ULiège
Promoteur(s) : Ruffoni, Davide ULiège
Date de soutenance : 8-sep-2025/9-sep-2025 • URL permanente : http://hdl.handle.net/2268.2/24796
Détails
Titre : Master thesis : Process validation in additive manufacturing for custom bone implants: Strategy and Optimization
Titre traduit : [fr] Validation de Procédé en Fabrication Additive pour Implants osseux sur Mesure : Stratégie et Optimisation"
Auteur : Malien, Téa ULiège
Date de soutenance  : 8-sep-2025/9-sep-2025
Promoteur(s) : Ruffoni, Davide ULiège
Membre(s) du jury : Nolens, Grégory 
Geris, Liesbet ULiège
Nolens, Grégory 
Langue : Anglais
Mots-clés : [en] process validation
[en] vat photopolymerization
[en] custom bone implants
[en] slurry
[en] internal structure orientation
[en] build position
[en] furnace load
Discipline(s) : Ingénierie, informatique & technologie > Multidisciplinaire, généralités & autres
Institution(s) : Université de Liège, Liège, Belgique
Diplôme : Master en ingénieur civil biomédical, à finalité spécialisée
Faculté : Mémoires de la Faculté des Sciences appliquées

Résumé

[en] Patient-specific bone implants produced via additive manufacturing offer a promising solution
for reconstructing maxillofacial bone defects that exceed the body’s natural healing capacity.
To ensure clinical reliability and be registered with the Food and Drug Administration, it is
essential to validate the manufacturing process in accordance with regulatory standards. While
additive manufacturing enables precise control over geometrical parameters, limited research at
Cerhum has explored how key process parameters affect the dimensional accuracy and mechanical
performance of the hydroxyapatite implants fabricated via vat photopolymerization.

This study investigated the effects of slurry condition, internal structure orientation, build
position and furnace load on the properties of hydroxyapatite gyroid-structured samples, as well
as the printability and dimensional accuracy of a worst-case sample. Three slurry conditions (new,
reused, expired) were tested, along with different orientations (X,Y,Z), build positions (intraand
intertile) and furnace loads (light, medium, maximum), in order to cover a representative
range of manufacturing conditions. Dimensional and mechanical measurements followed ISO
13175-3 standards, complemented by analyses of phase purity, porosity, heavy metal content and
carbon residues.

Results showed that all tested samples met phase purity and porosity requirements. Mean
dimensions remained within Cerhum’s tolerance range and indentation stresses corresponded to
physiological values for trabecular bone, providing preliminary validation of the manufacturing
process. However, the experimental design limited the reliable conclusions regarding the individual
influence of process parameters and their interactions, hindering the study’s objectives.
Preliminary findings suggested an impact of intertile position on dimensional and mechanical
properties. Orientation along the Z-axis yielded the best dimensional accuracy, while its effect
on mechanical performance varied across slurries but tended to be detrimental. Slurry condition
also proved influential, with the expired batch unexpectedly showing improved mechanical performance.
Importantly, all tested implants nevertheless remained within acceptable dimensional
and mechanical ranges, supporting the robustness of the process.

Further work should focus on revising the worst-case sample and refining the experimental
design by reducing the number of parameters and levels to extract reliable and interpretable
results.


Fichier(s)

Document(s)

File
Access TFE_MALIEN_Téa.pdf
Description:
Taille: 11.39 MB
Format: Adobe PDF

Annexe(s)

File
Access TFE_MALIEN_Téa_Summary.pdf
Description:
Taille: 143.3 kB
Format: Adobe PDF

Auteur

  • Malien, Téa ULiège Université de Liège > Master ing. civ. biom. fin. spéc.

Promoteur(s)

Membre(s) du jury

  • Nolens, Grégory
  • Geris, Liesbet ULiège Université de Liège - ULiège > Département d'aérospatiale et mécanique > Génie biomécanique
    ORBi Voir ses publications sur ORBi
  • Nolens, Grégory Cerhum








Tous les documents disponibles sur MatheO sont protégés par le droit d'auteur et soumis aux règles habituelles de bon usage.
L'Université de Liège ne garantit pas la qualité scientifique de ces travaux d'étudiants ni l'exactitude de l'ensemble des informations qu'ils contiennent.