Feedback

Faculté des Sciences appliquées
Faculté des Sciences appliquées
Mémoire
VIEW 24 | DOWNLOAD 1

Study, development and tests of two methods to determine the degree of linear polarization of auroral light

Télécharger
Jottrand, Félix ULiège
Promoteur(s) : Loicq, Jerôme ULiège
Date de soutenance : 7-sep-2020/9-sep-2020 • URL permanente : http://hdl.handle.net/2268.2/10180
Détails
Titre : Study, development and tests of two methods to determine the degree of linear polarization of auroral light
Titre traduit : [fr] Etude, développement et tests de deux méthodes pour déterminer le degré de polarisation linéaire des lumières aurorales
Auteur : Jottrand, Félix ULiège
Date de soutenance  : 7-sep-2020/9-sep-2020
Promoteur(s) : Loicq, Jerôme ULiège
Membre(s) du jury : Lamy, Hervé 
Grodent, Denis ULiège
Blain, Pascal ULiège
Langue : Anglais
Discipline(s) : Ingénierie, informatique & technologie > Ingénierie aérospatiale
Institution(s) : Université de Liège, Liège, Belgique
Diplôme : Master en ingénieur civil en aérospatiale, à finalité spécialisée en "aerospace engineering"
Faculté : Mémoires de la Faculté des Sciences appliquées

Résumé

[en] This master thesis presents two instruments to determine the degree of linear polarization of au-roral light using Stokes parameters. Both instrumentation will focus on the three brightest linesof the visible spectrum:λ=427.8 nm,λ=577.7 nm andλ=630.0 nm. The first method uses atelescope to collect the light and a spectropolarimeter to disperse it. Optical devices are added tomanipulate the light and alter polarization before the spectropolarimeter. It has faced significantlow flux reception during previous missions that prevented to obtain accurate results. For that rea-son, a complete radiometric budget followed by a modelisation in CODE V of the light path wererealised to first quantify and then minimize these losses, mainly located at the exit of the telescopeand at the matcher of the spectropolarimeter. The outputs of this study allowed to increase thesignal-to-noise ratio of the detector. The second instrument directly selects the wavelength thanksto a set of two acousto-optic tunable filters, which replaces the function of the telescope and thespectropolarimeter. Experimental tests using laboratory lasers were run to calibrate and evaluatethe response of the instrument in frequency for each wavelength. This instrument has been usedin an auroral observation ground mission in Norway, which showed the good functioning of theinstrument. Unfortunately, the auroral light emission was poor in intensity and the results werenot enough convincing. As both instrumentation use different ways to diffract light, a comparisonof the two methods can be considered. Finally, an adaptation for more extreme conditions, suchas low temperature and pressure is presented at the end of this report.


Fichier(s)

Document(s)

File
Access TFE_Felix_JOTTRAND.pdf
Description: -
Taille: 20.62 MB
Format: Adobe PDF
File
Access Erratum_TFE_Felix_JOTTRAND.pdf
Description: -
Taille: 92.04 kB
Format: Adobe PDF

Annexe(s)

File
Access Abstract_Felix_JOTTRAND.pdf
Description: -
Taille: 87.08 kB
Format: Adobe PDF

Auteur

  • Jottrand, Félix ULiège Université de Liège > Master ingé. civ. aérospat., à fin.

Promoteur(s)

Membre(s) du jury

  • Lamy, Hervé IASB > IASB > IASB
  • Grodent, Denis ULiège Université de Liège - ULiège > Département d'astrophys., géophysique et océanographie (AGO) > Labo de physique atmosphérique et planétaire (LPAP)
    ORBi Voir ses publications sur ORBi
  • Blain, Pascal ULiège Université de Liège - ULiège > CSL (Centre Spatial de Liège)
    ORBi Voir ses publications sur ORBi
  • Nombre total de vues 24
  • Nombre total de téléchargements 1










Tous les documents disponibles sur MatheO sont protégés par le droit d'auteur et soumis aux règles habituelles de bon usage.
L'Université de Liège ne garantit pas la qualité scientifique de ces travaux d'étudiants ni l'exactitude de l'ensemble des informations qu'ils contiennent.