Feedback

Faculté des Sciences
Faculté des Sciences
Mémoire
VIEW 73 | DOWNLOAD 1

Investigating Dioxins and PCBs analysis by APGC-Trapped Ion Mobility-Mass Spectrometry.

Télécharger
Muller, Hugo ULiège
Promoteur(s) : Eppe, Gauthier ULiège
Date de soutenance : 20-jan-2021 • URL permanente : http://hdl.handle.net/2268.2/11747
Détails
Titre : Investigating Dioxins and PCBs analysis by APGC-Trapped Ion Mobility-Mass Spectrometry.
Titre traduit : [fr] Recherche sur l'analyse des Dioxines et des PCBs par APGC-TIMS-MS
Auteur : Muller, Hugo ULiège
Date de soutenance  : 20-jan-2021
Promoteur(s) : Eppe, Gauthier ULiège
Membre(s) du jury : Focant, Jean-François ULiège
Scholl, Georges ULiège
Preud'Homme, Hugues 
Langue : Anglais
Nombre de pages : 84
Mots-clés : [en] Mass spectrometry
[en] Ion mobility
[en] Trapped ion mobility spectrometry
[en] Dioxin
[en] Furan
[en] PCB
[en] Pollutant
[en] Environment
[en] Food
[en] Feed
Discipline(s) : Physique, chimie, mathématiques & sciences de la terre > Chimie
Centre(s) de recherche : Mass Spectrometry Laboratory
Public cible : Chercheurs
Professionnels du domaine
Etudiants
Institution(s) : Université de Liège, Liège, Belgique
Diplôme : Master en sciences chimiques, à finalité approfondie
Faculté : Mémoires de la Faculté des Sciences

Résumé

[en] Over the last few years, the combination of ion mobility with mass spectrometry has gained interest in a variety of analytical fields, including trace pollutants analysis in complex matrices such as environmental and food samples. This technique separates ions according to their ion mobility in the gas phase (diffusion speed under the influence of an electrical field in a pressurized cell) and provides an additional dimension to the traditional GC/LC-MS systems, a higher selectivity and a noise reduction which lead to signal-to-noise ratios improvement. Collision cross-section, which is related to the charge state, size, and shape of the ion can be derived from the measurement of ion mobility. Trapped Ion Mobility Spectrometer (TIMS) was recently introduced and offers a more compact design with an improved ion mobility resolving power (up to 400) compared to other commercially available IM instruments. As a recent technique, it still needs to make its proof in analytical chemistry while coupled to gas chromatography mass spectrometry using an APCI source. In this master thesis, we investigated the potential of the APGC-TIMS-MS coupling applied to small persistent organic pollutants (POPs) like dioxins and polychlorobiphenyl derivatives (PCBs). We found that a complete mobility separation of dioxins and PCB congeners was achievable in the CCS frame according to their chlorination degree, while non baseline separation was usually reached for isomeric congeners. We also highlighted issues with the IMS calibration in the present coupling and proposed different methods for on-line calibration. We produced data supporting that the calibration was truly dependent on the source conditions and that internal and external calibrations both fail to provide absolute and accurate CCS. Calibration based on the chemical background from the GC column (polysiloxanes), shows an interesting potential in this regard.


Fichier(s)

Document(s)

File
Access Master Thesis - Hugo Muller.pdf
Description: -
Taille: 7.88 MB
Format: Adobe PDF

Auteur

  • Muller, Hugo ULiège Université de Liège > Master en sc. chimiques, à fin.

Promoteur(s)

Membre(s) du jury

  • Focant, Jean-François ULiège Université de Liège - ULiège > Département de chimie (sciences) > Chimie analytique, organique et biologique
    ORBi Voir ses publications sur ORBi
  • Scholl, Georges ULiège Université de Liège - ULiège > Département de chimie (sciences) > Center for Analytical Research and Technology (CART)
    ORBi Voir ses publications sur ORBi
  • Preud'Homme, Hugues
  • Nombre total de vues 73
  • Nombre total de téléchargements 1










Tous les documents disponibles sur MatheO sont protégés par le droit d'auteur et soumis aux règles habituelles de bon usage.
L'Université de Liège ne garantit pas la qualité scientifique de ces travaux d'étudiants ni l'exactitude de l'ensemble des informations qu'ils contiennent.