Feedback

Faculté des Sciences appliquées
Faculté des Sciences appliquées
Mémoire
VIEW 37 | DOWNLOAD 1

Design optimization of far UV spectro-imagers for ionosphere characterization from space

Télécharger
Rapallo, Valentin ULiège
Promoteur(s) : Loicq, Jerôme ULiège
Date de soutenance : 6-sep-2021/7-sep-2021 • URL permanente : http://hdl.handle.net/2268.2/13014
Détails
Titre : Design optimization of far UV spectro-imagers for ionosphere characterization from space
Titre traduit : [fr] Optimisation de la conception de spectro-imageurs dans l'UV lointain pour la caractérisation de l'ionosphère depuis l'espace
Auteur : Rapallo, Valentin ULiège
Date de soutenance  : 6-sep-2021/7-sep-2021
Promoteur(s) : Loicq, Jerôme ULiège
Membre(s) du jury : Kintziger, Christian ULiège
Habraken, Serge ULiège
Hubert, Benoît ULiège
Langue : Anglais
Nombre de pages : xii, 74 (86 total)
Mots-clés : [en] far ultraviolet
[en] spectrographic imager
[en] wavelength rejection
Discipline(s) : Ingénierie, informatique & technologie > Ingénierie aérospatiale
Institution(s) : Université de Liège, Liège, Belgique
Diplôme : Master en ingénieur civil en aérospatiale, à finalité spécialisée en "aerospace engineering"
Faculté : Mémoires de la Faculté des Sciences appliquées

Résumé

[en] In the context of a space mission aiming at characterizing the phenomenon of mag-
netic reconnection, a spectrographic imager is needed to gather data in the far ul-
traviolet domain. Its observation target is set to the polar aurora, in the ionosphere
of the Earth, as their emission spectra contain valuable information. Specificaly, the
instrument is expected to feature two channels, at wavelengths around the atomic
hydrogen Lyman-alpha emission line (at 121.567 nm) and around a specific atomic
oxygen emission line (at 135.6 nm).
The geocoronal Lyman-alpha emission of atomic hydrogen being much brighter
than the emission of the proton aurora, it may impair the instrument’s ability to
image the Doppler-shifted auroral Lyman-alpha. Therefore, it must be rejected to
prevent the detector from saturating and effectively rendering information around
that wavelength unusable. To solve this problem, the chosen method is a pair of slit
grilles, which is to be placed at the entrance and exit planes of the spectrographic
part of the instrument. Moreover, considering that the observation targets lie in the
far ultraviolet domain and are quite close one another, a Czerny-Turner design with
a diffraction grating is chosen for the aforementioned spectrographic element.
Thanks to specific softwares, an optical optimization of the setup can be per-
formed. For the channel pertaining to the Doppler-shifted Lyman-alpha emissions,
specific care is given to the computed leakage of the geocoronal emission and trans-
mission of the neighboring wavelengths.


Fichier(s)

Document(s)

File
Access Valentin Rapallo - Design optimization of Far UV spectro-imagers [abs].pdf
Description: Abstract
Taille: 68.87 kB
Format: Adobe PDF
File
Access Valentin Rapallo - Design optimization of Far UV spectro-imagers [txt].pdf
Description: Thesis
Taille: 9.65 MB
Format: Adobe PDF

Auteur

  • Rapallo, Valentin ULiège Université de Liège > Master ingé. civ. aérospat., à fin.

Promoteur(s)

Membre(s) du jury

  • Nombre total de vues 37
  • Nombre total de téléchargements 1










Tous les documents disponibles sur MatheO sont protégés par le droit d'auteur et soumis aux règles habituelles de bon usage.
L'Université de Liège ne garantit pas la qualité scientifique de ces travaux d'étudiants ni l'exactitude de l'ensemble des informations qu'ils contiennent.