Evaluation of the electrical consumption of an RTO and estimation of its emission reduction potential
Graas, Aymeric
Promoteur(s) : Scholzen, Frank ; Andre, Philippe
Date de soutenance : 25-jui-2022/7-jui-2022 • URL permanente : http://hdl.handle.net/2268.2/14917
Détails
Titre : | Evaluation of the electrical consumption of an RTO and estimation of its emission reduction potential |
Titre traduit : | [fr] Évaluation de la consommation électrique d'un RTO et estimation de son potentiel de réduction des émissions |
Auteur : | Graas, Aymeric |
Date de soutenance : | 25-jui-2022/7-jui-2022 |
Promoteur(s) : | Scholzen, Frank
Andre, Philippe |
Membre(s) du jury : | Skerdilajda, Zanaj
Walheer, Barnabé Ehlert, Christina |
Langue : | Anglais |
Nombre de pages : | 106 |
Mots-clés : | [en] electricity consumption, [en] LIST [en] Greenhouse gas emissions |
Discipline(s) : | Ingénierie, informatique & technologie > Energie |
Organisme(s) subsidiant(s) : | / |
Centre(s) de recherche : | Luxembourg Institute of Science and Technology |
Intitulé du projet de recherche : | / |
Public cible : | Professionnels du domaine |
Institution(s) : | Université de Liège, Liège, Belgique |
Diplôme : | Master en sciences et gestion de l'environnement, à finalité spécialisée en énergies renouvelables et bâtiments durables |
Faculté : | Mémoires de la Faculté des Sciences |
Résumé
[en] Given the current global warming context and greenhouse gas obligations for organisations, the Luxembourg Institute of Science and Technology established a carbon footprint that revealed a high emission related to its electricity consumption within its laboratory research building. As a result, the LIST has set itself the goal of reducing its consumption and greenhouse gas emissions through a variety of sustainable actions. We used the DMAIC method in conjunction with the EN16247 energy audit method to accomplish this. This combination revealed a lack of data on the Belvaux site's electricity consumption and greenhouse gas emissions. The proposals for improvement thus focused on three levels of correction and improvement: the implementation of centralized management and measurement, consumption reduction, and the implementation of renewable electricity production systems. In conclusion, thanks to this method we have been able to implement adapted and sustainable improvements to reduce the carbon footprint of this Institute. However, while this approach was sufficient to reduce unnecessary consumption, additional improvements could be considered to make this building environmentally responsible and energy efficient.
Fichier(s)
Document(s)
Description:
Taille: 6.6 MB
Format: Adobe PDF
Citer ce mémoire
L'Université de Liège ne garantit pas la qualité scientifique de ces travaux d'étudiants ni l'exactitude de l'ensemble des informations qu'ils contiennent.