Title : Modelling and Simulation Framework for Assessing Heat Pump Systems in BEV Trucks Volvo Group
Translated title : [fr] Développement d'un cadre de modélisation et de simulation pour l'évaluation de systèmes de pompe à chaleur dans les camions électriques à batterie
Author : Alchair, Adrien ULiège
Date of defense  : 7-Sep-2026/8-Sep-2026
Advisor(s) : Lemort, Vincent ULiège
Committee's member(s) : Gendebien, Samuel ULiège
Andric, Jelena 
Al Haddad, Rabih 
Language : English
Number of pages : 128
Keywords : [en] Electric vehicles
[en] thermal managament
[en] heat pump
[en] reduced-order model
Discipline(s) : Engineering, computing & technology > Mechanical engineering
Institution(s) : Université de Liège, Liège, Belgique
Degree: Master en ingénieur civil mécanicien, à finalité spécialisée en technologies durables en automobile
Faculty: Master thesis of the Faculté des Sciences appliquées

Abstract

[en] With the increasing adoption of electric vehicles, vehicle range remains one of the main challenges to their
adoption, particularly for heavy-duty vehicles that are required to travel long distances. In addition to the
energy required for propulsion, heating and cooling systems can significantly affect the overall energy con
sumption and range of electric vehicles. Consequently, the optimisation of thermal management systems
is an important aspect of electric vehicle development.
This master thesis develops and assesses a reduced-order, component-based modelling framework to
assess the potential performance of heat pump systems in battery electric vehicle (BEV) trucks. The
framework couples thermal models of the cabin, battery pack, and electric motor with a thermodynamic
heat pump model, and is used to identify the dominant operating parameters governing thermal and en
ergetic performance, and the conditions under which heat pump integration provides an energetic benefit.
Reduced-order models were used to provide a balance between the physical representation of the different
thermal phenomena and the computational efficiency required for system-level simulations. The individual
component models were then assessed against available reference data. The cabin model was compared
with CFD results, while the battery and electric motor models were compared with experimental data.
The models were able to reproduce the main thermal trends observed in the reference data.
The component models, calibrated and assessed against available reference data, were then com
bined within a reference thermal management architecture including a reversible heat pump for cabin
thermal management and a coolant loop for battery thermal management. The complete system was
evaluated through a series of representative steady-state operating scenarios covering different ambient
temperatures, vehicle speeds, truck loads, and charging power levels. Several performance indicators were
considered to assess the energetic performance of the system, including the heat pump coefficient of
performance (COP), system COP, and electrical energy consumption.
The results show that ambient temperature is the main parameter affecting heat pump performance.
At low ambient temperatures, the COP decreases significantly, resulting in increased electrical energy con
sumption. Vehicle speed mainly affects heat exchanger performance and heat transfer between the cabin
and the ambient environment, while higher charging power increases the cooling demand of the battery
pack. Overall, the results indicate that the heat pump can significantly reduce the electrical energy required
for cabin heating compared with a direct electric heating system, particularly at low ambient temperatures.
A comparison with available real-world truck data also showed a similar overall trend in terms of the
energy consumption associated with thermal auxiliaries. However, this comparison should be considered as
an indicative assessment, as no real-world data corresponding to a truck equipped with a heat pump were
available. Furthermore, the complete thermal management system has not been experimentally validated.
The developed framework therefore provides a basis for evaluating and comparing alternative thermal ar
chitectures and future control strategies.
Several limitations remain to be addressed. The current framework is based on steady-state sim
ulations and therefore does not capture transient vehicle operation. In addition, no detailed thermal
management control strategy is currently implemented, and system-level experimental validation remains
to be performed. Future work should therefore focus on extending the framework towards dynamic sim
ulations, implementing appropriate control strategies, and validating the complete system experimentally.
The assessment of alternative and more integrated thermal management architectures also represents an
important perspective for further improving the thermal and energetic performance of BEV trucks.


File(s)

Document(s)

File
Access Master_Thesis_Alchair_Adrien.pdf
Description:
Size: 6.77 MB
Format: Adobe PDF
File
Access Master_Thesis_Summary_Alchair_Adrien.pdf
Description:
Size: 111.16 kB
Format: Adobe PDF

Author

  • Alchair, Adrien ULiège Université de Liège > Master ing. civ. méc. fin. spéc. techno. dur. auto.

Promotor(s)

Committee's member(s)

  • Gendebien, Samuel ULiège Université de Liège - ULiège > Département d'aérospatiale et mécanique > Thermodynamique
    ORBi View his publications on ORBi
  • Andric, Jelena
  • Al Haddad, Rabih








All documents available on MatheO are protected by copyright and subject to the usual rules for fair use.
The University of Liège does not guarantee the scientific quality of these students' works or the accuracy of all the information they contain.