- Simulation of control strategies for small-scale pumped-storage plants including the use of pumps as turbines- Hydro-B S.A.
Warland, Lucas
Promotor(s) :
Hillewaert, Koen
Date of defense : 7-Sep-2026/8-Sep-2026 • Permalink : http://hdl.handle.net/2268.2/27036
Details
| Title : | - Simulation of control strategies for small-scale pumped-storage plants including the use of pumps as turbines- Hydro-B S.A. |
| Translated title : | [fr] Simulation de stratégies de régulation pour des stations de pompage-turbinage de petite taille, incluant l'utilisation de pompes en mode turbine |
| Author : | Warland, Lucas
|
| Date of defense : | 7-Sep-2026/8-Sep-2026 |
| Advisor(s) : | Hillewaert, Koen
|
| Committee's member(s) : | Erpicum, Sébastien
Dewallef, Pierre
Chaudoir, Frederic |
| Language : | English |
| Number of pages : | 122 |
| Keywords : | [en] PHS [en] PAT [en] Pumped Storage [en] Pumps as Turbine |
| Discipline(s) : | Engineering, computing & technology > Energy |
| Institution(s) : | Université de Liège, Liège, Belgique |
| Degree: | Master : ingénieur civil en génie de l'énergie à finalité spécialisée en Energy Conversion |
| Faculty: | Master thesis of the Faculté des Sciences appliquées |
Abstract
[en] In a small-scale pumped-storage plant the gross head varies over a large fraction of its mean value
during a single cycle, so the machines never settle at one duty point and the way they are controlled
decides how much energy comes back. This work quantifies that dependence and compares the
machines such a plant can use, in particular a standard pump run in reverse during the discharge.
A simulation tool was developed for that purpose. It resolves at each time step the equilibrium
between the machines, the hydraulic circuit and the two reservoirs whose levels it updates, the
machines being described by characteristic curves transposed by the similarity laws or by a hill
chart. Three control strategies are implemented, fixed speed, tracking of the best efficiency point
and constant power, and the model is applied to two Belgian projects, Temse and Zutendaal. A
standard pump was also characterised in both modes on the test bench of the University of Liège.
Tracking the best efficiency point brings the round-trip efficiency of the pump-as-turbine configuration to 65.8 % at Temse and 66.5 % at Zutendaal, against 63.7 % and 62.6 % at fixed speed,
but the converter it requires consumes most of that gain. Constant power costs fourteen points at
Temse and is unattainable at Zutendaal, a machine without guide vanes holding the setpoint only
far from its best efficiency point. A pump used as a turbine gives up between eight and twelve points
of recovered energy against a dedicated machine.
None of the three strategies dominates the other two, the ranking depending on whether the operator
is paid for the energy returned or committed to a firm power. Variable speed pays only where the
head varies enough to exceed the cost of the drive, and a separate pump and turbine remains the better arrangement at both sites on performance grounds.
File(s)
Document(s)
Cite this master thesis
The University of Liège does not guarantee the scientific quality of these students' works or the accuracy of all the information they contain.

Master Thesis Online


All files (archive ZIP)
TFE_LucasWarland.pdf
Résumé_TFE_Lucas_Warland.pdf