Feedback

Faculté des Sciences appliquées
Faculté des Sciences appliquées
Mémoire
VIEW 128 | DOWNLOAD 236

Development of a methodology for VLEO intake performance testing in a low density facility

Brabants, Coralie ULiège
Promoteur(s) : Hillewaert, Koen ULiège
Date de soutenance : 24-jui-2021/25-jui-2021 • URL permanente : http://hdl.handle.net/2268.2/11557
Détails
Titre : Development of a methodology for VLEO intake performance testing in a low density facility
Auteur : Brabants, Coralie ULiège
Date de soutenance  : 24-jui-2021/25-jui-2021
Promoteur(s) : Hillewaert, Koen ULiège
Membre(s) du jury : Dewallef, Pierre ULiège
Magin, Thierry ULiège
Langue : Anglais
Discipline(s) : Ingénierie, informatique & technologie > Ingénierie aérospatiale
Centre(s) de recherche : Von Karman Institut
Institution(s) : Université de Liège, Liège, Belgique
Diplôme : Master en ingénieur civil en aérospatiale, à finalité spécialisée en "aerospace engineering"
Faculté : Mémoires de la Faculté des Sciences appliquées

Résumé

[en] The objective of this thesis is to design a test procedure within a high vacuum installation with the aim of providing the transmissivity to a fast flux of particles. This parameter is of paramount importance to the evaluation of the intake performance.

First, the pressure evolution within the two chambers of the installation is simulated based on a 0-D model implemented in MATLAB. The model is based on kinetic theory and determines an expression for all the flows circulating in the vacuum facility.
It allows defining the various factors impacting the facility operation and the relevant intake perfomance parameters.

Then, a series of tests is proposed. These are required to determine all facility operational parameters which are not measurable directly or within a single test. Two assumptions are considered to determine the intake performance. We will show that one can provide slightly more precise measurements than the other

Finally, an analysis of the error propagation is realized to estimate the uncertainty of the test results.
The large uncertainties associated with some of the tests increase the uncertainty associated to the fast flux transmissivity estimative.
This uncertainty depends not only on the analytical reasoning chosen but also on the configuration.
The developed 0-D model and uncertainty propagation will be used in the future to assist in the configuration definition of the VKI low density facility. Moreover, the 0-D model will be valuable to retrieve the relevant transmissivities from interpretation of each chamber pressure.


Fichier(s)

Document(s)

File
Access S195970CoralieBrabants2021.pdf
Description: -
Taille: 2.35 MB
Format: Adobe PDF

Annexe(s)

File
Access Annex.pdf
Description: -
Taille: 185.32 kB
Format: Adobe PDF

Auteur

  • Brabants, Coralie ULiège Université de Liège > Master ingé. civ. aérospat., à fin.

Promoteur(s)

Membre(s) du jury

  • Dewallef, Pierre ULiège Université de Liège - ULiège > Département d'aérospatiale et mécanique > Systèmes de conversion d'énergie pour un dévelop.durable
    ORBi Voir ses publications sur ORBi
  • Magin, Thierry ULiège Université de Liège - ULiège > Département d'aérospatiale et mécanique > Département d'aérospatiale et mécanique
    ORBi Voir ses publications sur ORBi
  • Nombre total de vues 128
  • Nombre total de téléchargements 236










Tous les documents disponibles sur MatheO sont protégés par le droit d'auteur et soumis aux règles habituelles de bon usage.
L'Université de Liège ne garantit pas la qualité scientifique de ces travaux d'étudiants ni l'exactitude de l'ensemble des informations qu'ils contiennent.