Design optimization of far UV spectro-imagers for ionosphere characterization from space
Rapallo, Valentin
Promotor(s) : Loicq, Jerôme
Date of defense : 6-Sep-2021/7-Sep-2021 • Permalink : http://hdl.handle.net/2268.2/13014
Details
Title : | Design optimization of far UV spectro-imagers for ionosphere characterization from space |
Translated title : | [fr] Optimisation de la conception de spectro-imageurs dans l'UV lointain pour la caractérisation de l'ionosphère depuis l'espace |
Author : | Rapallo, Valentin |
Date of defense : | 6-Sep-2021/7-Sep-2021 |
Advisor(s) : | Loicq, Jerôme |
Committee's member(s) : | Kintziger, Christian
Habraken, Serge Hubert, Benoît |
Language : | English |
Number of pages : | xii, 74 (86 total) |
Keywords : | [en] far ultraviolet [en] spectrographic imager [en] wavelength rejection |
Discipline(s) : | Engineering, computing & technology > Aerospace & aeronautics engineering |
Institution(s) : | Université de Liège, Liège, Belgique |
Degree: | Master en ingénieur civil en aérospatiale, à finalité spécialisée en "aerospace engineering" |
Faculty: | Master thesis of the Faculté des Sciences appliquées |
Abstract
[en] In the context of a space mission aiming at characterizing the phenomenon of mag-
netic reconnection, a spectrographic imager is needed to gather data in the far ul-
traviolet domain. Its observation target is set to the polar aurora, in the ionosphere
of the Earth, as their emission spectra contain valuable information. Specificaly, the
instrument is expected to feature two channels, at wavelengths around the atomic
hydrogen Lyman-alpha emission line (at 121.567 nm) and around a specific atomic
oxygen emission line (at 135.6 nm).
The geocoronal Lyman-alpha emission of atomic hydrogen being much brighter
than the emission of the proton aurora, it may impair the instrument’s ability to
image the Doppler-shifted auroral Lyman-alpha. Therefore, it must be rejected to
prevent the detector from saturating and effectively rendering information around
that wavelength unusable. To solve this problem, the chosen method is a pair of slit
grilles, which is to be placed at the entrance and exit planes of the spectrographic
part of the instrument. Moreover, considering that the observation targets lie in the
far ultraviolet domain and are quite close one another, a Czerny-Turner design with
a diffraction grating is chosen for the aforementioned spectrographic element.
Thanks to specific softwares, an optical optimization of the setup can be per-
formed. For the channel pertaining to the Doppler-shifted Lyman-alpha emissions,
specific care is given to the computed leakage of the geocoronal emission and trans-
mission of the neighboring wavelengths.
File(s)
Document(s)
Description: Abstract
Size: 68.87 kB
Format: Adobe PDF
Description: Thesis
Size: 9.65 MB
Format: Adobe PDF
Cite this master thesis
The University of Liège does not guarantee the scientific quality of these students' works or the accuracy of all the information they contain.